Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/18/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/17/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 11/16/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) WILL APPROVE WHEN ALL TRADES ARE COMPLETE 2) STRAP DBL TOP PLATE AT KITCHEN 3) DBL PLATE AS PER NOT ON PLANS 4) REMOVE SCREEN FROM DRYER VENT 5) INSULATE BEHIND TUBS |
|
| 11/15/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/12/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEAL PENETRATION AT CLEANOUT WEST WALL 2) COACH LIGHT FIXTURE BOXES NOT GROUNDED 3) ANCHOR BOLTS MISSING AT GARAGE INTERIOR WALL, CLIP MISSING NAIL 4) BLOCK MISSING AT SHEAR TRANSFER 5) NEED 9" OF SPACE UNDER FAU PLATFORM 6) STUD MISSING AT KITCHEN WALL FIXTURE BOXES NOT GROUNDED 7) ANCHOR BOLT MISSING AT ENTRY UNDER W.H. PLATFORM WITHIN 12" FROM END OF PLATE 8) PIPES AND WATER LINES WET 9) STOPPED INSPECTION, TO MANY ITEMS |