Permit: T04CM03124

Parcel: 138133220

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/04/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*/ 1) HOLDOWN TO BE ADDED ON INTERIOR AT END OF SHEAR EAST OF S.G.D. 2) STRETCH STRAPS BETWEEN FLOOR/10" MINIMUM LAP 3) COMPLY WITH 7/SD3 4) 2-2 X 4 REQUIRED AT FRONT PORCH BEAM/TRIMMERS
09/28/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NO LOT NUMBERS OR ADDRESS ON SITE, COULD NOT FIND JOB 2) GARAGE REQUIRES 2 KING STUDS 1 TRIMMER 3) KITCHEN HOLDOWN WRONG LOCATION, NOT AT END OF SHEAR WALL 4) 1/SD2 CS 20 STRAPS TO SHORT 5) STOPPED INSPECTION TOO MANY ITEMS
09/27/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PROVIDE WIND BRACE AT EAST NORTH SIDE AT 2ND FLOOR