Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
12/20/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) FIREBLOCK UNDER TUBS 2) SUPPORT ABS WITH BLOCKS, NOT STRAPS 3) NAIL STRAPS 2" ABS 4) NO DWV WATER TEST 5) NEED 1" CLEARANCE TO B-VENT AT ROOF |