Permit: T04CM03009

Parcel: 11516040B


Addresses:

975 W GRANT RD #105

Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Date Description Inspector Results Comments
08/18/2004 PLUMBING - PROGRESS Approved IVRS - Inspection :*/APP
1)ALL PIPING TO BE SUPPORTED AT THE END OF GRANCHES, CHANGES OF ELEVATION, AND CHANGES OF DIRECTION, AND THEN EVERY SO MANY FEET ACCORDING TO TABLE 3-1 94UPC
2)ALL CLEAN-OUTS UTILIZING A CHROME COVER, REQUIRE A COUNTER SINK TAPPED PLUG W/MACHINE SCREW.
3) IT IS NEVER A GOOD IDEA TO MIX COPPER AND GALVANIZED PIPE.