Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/11/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GROUND ALL METAL ELECTRIC BOXES 2) STAIR RISE AND RUN CANNOT BE MORE THAN 38" DIFFERENCE AND RUNS CANNOT BE LESS THAN 10" FROM NOSE TO NOSE 3) NAIL PROTECT ALL WIRES WITHIN 1 1/4" OF STUD SURFACE 4) SUMP PUMP MISSING REQUIRED GATE VALVES IN UNIONS 5) NAIL TOP FLOOR WALL BOTTOM PLATE TO FLOOR AT 16" ON CENTER |
|
| 01/04/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE PLUMBING WALL DOWNSTAIRS BATH 2) SEAL PENETRATIONS AT CONDUIT TO MAIN SERVICE AND EXTERIOR 3) NAIL PROTECT ROMEX UPSTAIRS MECHANICAL CHASE 4) NAIL PROTECT VENT UPSTAIRS 5) NAIL PROTECT ALL VENTS UNDER 1/2 CLEARANCE 6) BLOCK ALL VENT 90'S 7) BLOCK REGISTERS ALL 3 SIDES |