Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/30/2004 BUILDING - FINAL Approved IVRS - Inspection :*
11/29/2004 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) IMPROPER COLOR CODED WIRES ON 2 220 VOLT CIRCUITS. WHITE WIRES CANNOT BE HOT
2) REMOVE DISUSED HOLDOWN TRIP HAZZARD
3) OUTSIDE HOSE BIB REQUIRES ANTI-SIPHON VALVE
4) AIR HANDLER HEAT STRIP LABEL MISSING
5) ATTIC DISCONNECT REQUIRES BUSHING OR ROMEX CLAMP
6) ACCESS TO ATTIC AIR HANDLER OBSTRUCTED BY DUCT WORK. REQUIRES 30" VERTICAL CLEARANCE
7) MASTER BATH LAV'S MISSING