Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/22/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/19/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) FRAMING WILL BE APPROVED , WHEN ALL TRADES ARE COMPLETE 2) ELECTRIC INTERMEDIATE WILL BE APPROVED WHEN GROUND ROD SYSTEM FOR UFER IS INSTALLED 3) NAIL PROTECT DRYER VENT 4) OK TO INSULATE |
|
| 11/18/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/15/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PROVIDE GROUND ROD SYSTEM FOR UFER 2) PANEL NEEDS 36" CLEARANCE FROM WINDOW 3) COACH LIGHT FIXTURE BOX MISSING GROUND SCREW 4) REPLACE 2 X 6 STUD AT KITCHEN WALL 5) NAIL PROTECT ELECTRIC AT KITCHEN 6) CLIP STUDS AT GLB STAIRS 7) NAIL PROTECT DRYER VENT 8) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT B-VENTS 9) FIRE BLOCK MECHANICAL CHASES INTO ATTIC 10) STOPPED INSPECTION |