Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/04/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT ELECTRIC WITHIN 1 1/4' FROM EDGE OF STUD |
|
| 11/02/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRAMING WILL BE APPROVED WHEN ALL TRADES COMPLETE 2) NAIL PROTECT ELECTRIC WITHIN 1 1/4" FROM EDGE OF STUD 3) W.C. AT MASTER BATH WILL NOT HAVE THE 15" CLEARANCE WHEN SHEETROCK IS INSTALLED |
|
| 11/01/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 10/29/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) LATH NOT COMPLETE |
|
| 10/27/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) LEAK IN KITCHEN DRAIN 2) TACK BATH WALL TOP PL. TO TRUSS 3) USE 16D COMMON NAILS IN ALL DBL GIRDER HANGER 4) SEE BACK MARKS ON FLOOR 5) CUT NAIL LOOSE PLATES 5) ROMEX BELOW CLOSET CEILING 6) BANG PLATE REAR ROMEX CABLE TOP PLATE 7) GAS PRESSURE OK 8) CHECK TUB LEAK MAYBE CRACKED |