Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T04CM02986
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/08/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
12/06/2004 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) ROOF: ALL SCREENS HAVE BEEN REMOVED FROM T-TOPS 2) EXTEND 1 1/4" VENT EASTSIDE 3) NEED RAIN COLLAR ON H20 HTR FLUE 4) CAULK FLUE TO ROOF JACK GAP (FURNACE) -----------------------------------------------------------------------------------------INSIDE: 1) NEED 1/8" PITCH PER FOOT CONDENSATE LINE 2) LEAVE FURNACE SPECS OR MARK FLUE'S AND UNIT FOR INTAKE EXHAUST 3) WIRE/ROMEX INSIDE FIREPLACE NOT CONNECTED |