Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/05/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/02/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DWV'S AND WATER LINES OK 2) GAS TEST AT 3 PSI, NEED 10 PSI 3) REMOVE SCREEN FROM DRYER VENT 4) BLOWN FIRE BLOCK AT HALL CLOSET 5) COMPY WITH DETAIL 10SD4 6) SHEAR PANELS ABOVE BATH (2 IN WRONG BAYS) |
|
| 10/29/2004 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection. Remove all insulation, drywall. House insulated and being rocked before intermediate inspections |
|
| 10/26/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) HOUSE INSULATED BEFORE INTERMEDIATES WHERE APPROVED. REMOV INSULATION AND MOVE DRYWALL AWAY FROM WALLS |
|
| 10/22/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |