Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM02976

Parcel: 140375650


Addresses:

7028 S PETREL LN

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/12/2004 FRAMING Approved IVRS - Inspection :*
11/08/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) BLOCKING PANELS ABOVE SHEARWALL MISSING
2) SHIM HEADER AT GARAGE ENTRY MAN DOOR
3) A35 CLIPS MISSING AT DRAG TRUSS
4) NAIL PROTECT ELECTRIC AND PLUMBING
5) STOPPED INSPECTION
10/27/2004 FRAMING Not ready for Inspection