Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/03/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) OVERHEAD WATER DISTRIBUTION IS OK. 3) OK FOR DRY WALL UPON BLDG INSPECTORS APPROVAL. | |
| 03/01/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NOT INSTALLED PER PLAN. PLAN CALLS FOR COPPER WATER PIPING. NO PROVISION MADE FOR INSULATION ON HOT WATER PIPING. NO INDIVIDUAL CONTROLS ON TUB AND SHOWER VALVES 2) IF DRAIN WASTE AND VENT WAS INSTALLED PER ISOMETRIC, WET VENTED SECTIONS ARE UNDER SIZED, IF NOT INSTALLED PER PLAN, NO RED LINES ON SITE 3) HORIZONTAL VENT PIPING OVER HEAD TO BE SUPPORTED |