Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/15/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 3P #4 SHEAR NOT PER PLAN 2) PROVIDE TERRITORIAL SHEAR PLAN 3) BR 2 SHEAR WALL 1 REQUIRED STUDS AT 16" ON CENTER PER 1/D3 AND BR 3 4) BLOCK BETWEEN LADDER BACK PER 1/D3 5) LESS THAN 2" CLEARANCE AT F/P 'B' VENT 6) RANGE BOX MISSING 7) RED HEAD A/B LOOSE 8) NO GAS BOND 9) SUPPORT VENT 90 ELBOW AT ROOF PENETRATION 10) SEAL MASTER BATH FROM OUTSIDE 11) FIRE STOP REQUIRES 2 LAYERS OF OSB 1/2" OR 1 3/4" |
|
| 12/13/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAILS MISSING AT ? TRUSS HANGER ABOVE WATER HEATER PLATFORM 2) FIRE STOP NEEDED SINGLE GARAGE DOOR WEST END 3) REPLACE FIRE BLOCK NORTH GARAGE WALL 4) SHIM HEADER REAR PORCH WINDOW 5) SEAL OUTLET BOX ABOVE SERVICE PANEL 6) GROUND ALL METAL BOXES 7) NAIL PROTECT ROMEX BELOW DINING ROOM WINDOW 8) NAIL PROTECT ROMEX THROUGHOUT HOME UNDER 1 1/4" 9) NAIL PROTECT PEX AT WATER SOFTNER 10) PROVIDE TRUSS CALC'S 11) DMV AND WATER TESTS OK |