Permit: T04CM02932

Parcel: 13104398A


Addresses:

4701 E 29TH ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/20/2005 PLUMBING - FINAL Approved IVRS - Inspection :*
NEED (4) IN HOUSE BACKFLOW CERTIFICATIONS FOR BUILDING INSPECTOR
09/08/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PAY REFEE, READ NOTES AND MAKE CORRECTIONS
2) HAVE YOUR PLUMBING CONTRACTOR ON SITE AT FUTURE INSPECTION. YOU HAVE INSTALLED A 4-COMP SINK WHERE A 2-COMP SINK IS SHOWN, PROVIDE WHATE IS PER PLAN OR REVISE YOUR PLAN. YOUR WATER HEATER REQUIRES AN EXPANSION TANK PER PLAN. READ ALL NOTES AND COMPLY
08/24/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) HAVE YOUR PLUMBING CONTRACTOR CONTACT ME
2) YOU DO NOT HAVE APPROVAL FOR USE OF ANY NEW EQUIPMENT OR MACHINES ON THIS SITE-DO NOT USE IT, UNTIL YOU HAVE APPROVAL
07/25/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) READ AND PROVIDE ITEMS FROM 6/14/05 INSPECTION
2) PROVIDE SEPERATE BACKFLOW PROTECTION FOR CARBONATER AND H20 TO NON-CARBONATED BEVERAGES
3) INDIRECT DRAINS ARE REQUIRED TO BE SEPERATE AND SUPPORTED PROPERLY. SEE NOTE #10
06/14/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) PROVIDE CLEANOUT COVERS. PROVIDE VACUUM BREAKERS FOR ALL HOSE BIBS. 2) HAVE ALL EQUIPMENT INSTALLED. 3) PROVIDE BACKFLOW PROTECTION OR PROOF OF 1" AIR GAP FOR ICE MAKER. 4) PROVIDE FULL SIZE ICE MAKER DRAIN TO APPROVED RECEPTOR. GRAVITY DRAIN ICE BIN DRAIN NO BACK PITCH & PROVIDE 1'' AIRGAP. 5) PROVIDE FULL SIZE DRAINAGE FOR 3-COMP SINK WITH CLEANOUT IN CORRECT LOCATION. 6) REMOVE DEMO COPPER DRAIN PIPING. 7) CAP ALL UN USED WASTE & VENT & H20 PIPING. 8) INSTALL CORRECT FAUCET AT JANITOR SINK. 9) MAKE JANITOR SINK WATER TIGHT. 10) ANY INDIRECT DRAIN OVER 5" REQUIRES A P-TRAP, OVER 15' REQUIRES TRAP & VENT. THIS MAY NOT BE COMPLETE LIST. 11) PROVIDE CERTIFICATION FOR ALL BACKFLOW DEVICES.