Permit: T04CM02928

Parcel: 115181570


Addresses:

520 W HELEN ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/04/2005 FRAMING Approved IVRS - Inspection :*
02/16/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LEDGER BOLTS LOOSE
2) HAVE PLAN REVISED FOR USE OF CORRIGATED STAINLESS
STEEL TUBING AND SIZED ACCORDINGLY
3) LPI JOISTS HAVE OVERSIZE HOLES TO CLOSE TO BEARING END
4) FIRE STOP 2ND FLOOR PENETRATIONS
5) FURNACE "B" VENT HORIZONTAL RUN MUST HAVE 1/4" FT PITCH
6) PROVIDE PEX PROTECTION
7) HORIZONTAL DWV REQUIRES 1/4" FT PITCH
8) STAIRS NOT IN
9) WIRING NOT COMPLETE
10) GAS PRESSURE TEST OK