Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 02/03/2005 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 02/01/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* 1) 2 COMPARTMENT SINK REQUIRES 2" P-TRAP. 2) PROVIDE ACCESS PANEL FOR RUST ROOM TRAP PRIMER VALUE. 3) PROVIDE BACKFLOW CERTIFICATION FOR ( 2) ?? FOR COOLING TOWER. 4) PROVIDE VACUUM BREAKER FOR HOSE BIB AT COOLING TOWER. 5) EXPOSE CLEANOUTS FOR VIEWING AT ALL LOCATIONS REQUIRED. 6) CALL IN 03036 FOR INSPECTION. |
| 01/14/2005 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/1)PROVIDE FINAL FOR SHELL BUILDING BEFORE CALLING T.I. FINAL 2)BOND POSTED FOR TEMP FUEL |