Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/03/2004 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :*/ 1) CORRECTIONS MADE OK 2) PLUMBING FINAL OK 3) OK FOR C OF O PENDING OTHER INSPECTIONS |
| 08/02/2004 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) SEE PLUMBING NOTE #6 ON P-1. ALL PENETRATIONS THRU WALL TO HAVE ESCUTCHEONS-ALL RECESSED. CLEAN-OUTS TO HAVE CP COVER PLATE 2) ALL FIXTURES TO BE CAULKED 3) SEE PLUMBING SPEC FOR LAV FCT. 4) FLOW CONTROL INSTALLED ON OUTLET SIDE OF TRAP-VENT MUST BE CONNECTED TO S.S. VENT 5) WHERE IS CLEANOUT AT K-4 FRONT COUNTER ? 6) INSPECTION STOPPED |
| 07/28/2004 |
PLUMBING - FINAL |
|
Partial Approval |
IVRS - Inspection :*PARTIAL APPROVAL. PLEASE PROVIDE TESTING ON BACKFLOW DEVICES. ALSO PROVIDE FUNNEL FOR CONDONSATE AND ANCHOR. |