Permit: T04CM02912

Parcel: 136081250


Addresses:

9531 E 30TH ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/29/2004 FRAMING Approved IVRS - Inspection :*
08/25/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) ADD POST FOR BEARING AT BUILT UP HEADER INTERIOR GARAGE 2) INSTALL 2 X 4 FOR POST BEARING SEE PLAN 3) HAVE DBL 2 X 10 HEADER PLAN CHECKED FOR SIZE 4) NOTCH IS LESS THAN 1/6-OK HAS 2 X 8 SCABS BOLTED 5) PAINT BOTTOM PLATE WITH WOOD PRESERVATIVE 6) ADD NAILS TO TIE HEADER TOGETHER PER PLAN CHECK 2 X 10 ROOF SYSTEM 24" ON CENTER 7) 18' SPAN 9'-7" HEADER