Permit: T04CM02903

Parcel: 118051280

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/07/2004 FRAMING Approved IVRS - Inspection :*
09/28/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) MAKE UP ALL GROUNDS AND SECURE WITH MECHANICAL FASTENERS 2) ALL ELECTRIC WIRES MUST TERMINATE IN APPROVED BOXES 3) GARAGE ELECTRIC OUTLETS MUST BE AT LEAST 18" ABOVE FLOOR 5) NO DWV WATER TEST PER UPC 712.2 6) ANCHOR BOLT SILL PLATE FOR BEARING POST AND CLIP BEARING POINTS 7) RANGE HOOD MUST EXHAUST OUTSIDE 8) PROVIDE ATTIC ACCESS 9) PLAN CALLS FOR METAL DUCT WORK, FLEX USED. BUILD TO PLAN OR HAVE PLAN REVISED TO AS BUILT 10) UNDERSIZE HEADER AT SLIDING GLASS DOOR 11) PLAN CALLS FOR HEAT PUMP ON ROOF, REVISE PLAN 12) HAVE TRUSS DRAWINGS APPROVED BY CITY OF TUCSON