Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/08/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | 1) TRUSS "A" REQUIRES POST UNDER POINT 16. 2) HAVE TRUSS DRAWINGS APPROVED BY CITY OF TUCSON. | |
| 09/03/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) MISSING H2.5/RSP4 CLIPS THROUGH OUT 2) NAIL PROTECT (FHA STRAP) PLUMBING WITHIN 1 1/4" OF PLATE SURFACES 3) REAR SHEAR NOT NAILED TO STUDS 4) TRUSSES NOT CLIPPED 5) LOOSE PANELS ON ROOF, RE-CHECK NAILING 6) TRUSS "A" NOT SUPPORTED AT POINT 16 7) STOPPED INSPECTION-TOO MANY ITEMS |