Permit: T04CM02903

Parcel: 118051280

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/28/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/08/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval 1) TRUSS "A" REQUIRES POST UNDER POINT 16. 2) HAVE TRUSS DRAWINGS APPROVED BY CITY OF TUCSON.
09/03/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) MISSING H2.5/RSP4 CLIPS THROUGH OUT 2) NAIL PROTECT (FHA STRAP) PLUMBING WITHIN 1 1/4" OF PLATE SURFACES 3) REAR SHEAR NOT NAILED TO STUDS 4) TRUSSES NOT CLIPPED 5) LOOSE PANELS ON ROOF, RE-CHECK NAILING 6) TRUSS "A" NOT SUPPORTED AT POINT 16 7) STOPPED INSPECTION-TOO MANY ITEMS