Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2004 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
| 09/24/2004 | SHEET ROCK NAILING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection. Plans call for 1 5/8" nails (5d) on #5 shear wall 1 1/8" screws used. Ok to tape house, not garage |
|
| 09/23/2004 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) #5 SHEAR WALL IN GARAGE NOT NAILED OVER 24" SPAN 2) #1 SHEAR WALL NAILED IN EXCESS OF 7" ON CENTER TOP AND BOTTOM PLATES 3) SHEARWALL STUDS NOT NAILED |
|