Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM02882

Parcel: 110034820

Inspection Status: Approved

Inspection History: ENGINEERING - FINAL

Date Description Inspector Results Comments
11/21/2006 ENGINEERING - FINAL Approved
11/17/2006 ENGINEERING - FINAL Partial Approval OK for temp, C of O. complete landing at rear exit doors prior to final C of O.
11/14/2006 ENGINEERING - FINAL Denied 1. PROVIDE A MINIMUM 4' SIDEWALK AT THE TRASH ENCLOSURE.
2. REPAIR BROKEN SIDEWALK AT R.O.W. ON PARADISE FALLS
ROAD.
3. REMOVE PIPE IN 10' SIDEWALK NEXT TO TELEPHONE PEDESTAL.
4. PROVIDE TRUNCATED DOMES AT SIDEWALK NEXT TO TRASH ENCLOSURE AND A PEDESTRIAN ACCESSWAYS AND RAMPS IN PARKING LOT.
5. INSTALL GATES ON TRASH ENCLOSURE.
6. INSTALL 4" THICK SHOTCRETE BANK PROTECTION FOR ROOF DRAINS AS SHOWN ON DETAIL 2, PAGE 5 OF THE REVISED GRADING PLAN.
7. PROVIDE BICYCLE PARKING AT SOUTHWEST CORNER OF BLDG.