Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/02/2007 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* ELEVATOR SHAFT COMPLETE @ 31'1" - GROUT & CAP |
|
| 04/30/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR SHAFT @ 28'8" -- OK TO GROUT |
|
| 04/27/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR SHAFT @ 25'8" -- OK TO GROUT PROGRESS AREAS |
|
| 04/25/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR SHAFT # 17'6" -- OK TO GROUT |
|
| 03/14/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH RADIUS WALL @ 13'4" LINE C/.5 TO D/.5 |
|
| 03/12/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED |
|
| 03/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH RADIUS WALL @ 9'4" OK TO GROUT |
|
| 03/01/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR SHAFT @ 14'6" -- OK TO GROUT EAST WALL EMBEDS TO BE MODIFIED WHEN HEIGHT IS DETERMINED AS PER ENGINEER -- OK TO GROUT |
|
| 02/23/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR SHAFT @ 8' - OK TO GROUT WEST WALL @ 16'6" LINE; C/1.5 TO C/4.5 - OK TO GROUT & CAP |
|
| 02/15/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR SHAFT 1ST LIFT @ 40" -- OK TO POUR |
|
| 02/13/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH, SOUTH AND EAST PERIMETER WALLS @ 29'4" OK TO GROUT |
|
| 02/08/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) NORTH, SOUTH AND EAST EXTERIOR WALLS AT 25'-4" OK TO GROUT |
|
| 02/06/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR AT 7'-8" LINE 2) B.5/5 TO C/1 OK TO GROUT |
|
| 01/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH BREAKROOM - TOPPED OUT @ 12' OK TO GROUT & CAP |
|
| 01/12/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH PORTION (BATHROOM/BREAKROOM) @ 8' - OK TO GROUT |
|
| 01/09/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* N, E, S EXTERIOR WALLS @ 18'4" -- OK TO GROUT |
|
| 01/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NORTH WALL OF BATHROOM/BREAKROOM @ 4' OK TO GROUP |
|
| 12/01/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR SHAFT @ 52" -- OK TO GROUT |
|
| 10/25/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* GRIDLINE D/ 1-2 IN COMPLIANCE WITH SPEC. INSP. REPORT 10/24/06 |
|
| 10/23/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINE D/1.5 TO D/2 @ 4' OK TO GROUT |
|
| 10/20/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PERIMETER WALLS @ 13'2" -- LOCATIONS FOR EMBEDDED PLATES APPLICATIONS AS PER SHOP DRAWINGS (OK TO GROUT) |
|
| 10/17/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* D/1.2 TO B/5 @ 12' OK TO GROUT |
|
| 10/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST WALL @ 10' -- OK TO POUR |
|
| 10/12/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* N&S WALLS @ 12' 4" OK TO POUR W WALL @ 8'4" OK TO POUR |
|
| 10/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* N, S, E WALLS @ 8' -- SW COLUMNS @ 5'8" |
|
| 10/04/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* S.W COLUMNS -- OK TO GROUT |
|
| 08/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR PERIMETER WALLS - 0' TO 4' OK TO GROUT NOTE: SOUTH WALL #5 REBAR USED; RAN OUT OF #4'S |
|
| 08/16/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 0'-24" OK TO POUR GROUT |