Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/05/2007 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* TOPPED OUT @ LINE E/3 TO E/4 |
|
| 04/02/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR WALLS @ 25' LINES B/4 TO E/4 EMBEDDED PLATES SET @ 23' - OK TO GROUT & CAP |
|
| 03/30/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
| 03/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH & WEST WALLS @ 25' LINES D/6 TO D.8/4 OK TO GROUT |
|
| 03/28/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR WALLS @ 25' -- LINES B/4 TO C/6 -- OK TO GROUT |
|
| 03/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR LINES B/4 TO D.8/4 AT 21'-4", D/2 TO B/3 AT 25' OK TO GROUT |
|
| 03/23/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* RAINED OUT |
|
| 03/20/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SECOND FLOOR @ 23'6" LINE B/3 TO D/1.3 OK TO GROUT |
|
| 03/19/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED |
|
| 03/16/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND FLOOR LINES: D/2 TO D.5/6 -- OK TO GROUT @ 40" |
|
| 03/14/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND FLOOR @ 32" - LINE C/6 THROUGH D/3 OK TO POUR; NORTHWEST STAIRWELL @ 13'4" -- OK TO POUR |
|
| 03/12/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED |
|
| 03/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NW EXTERIOR STAIR WELL @ 9'4" -- OK TO GROUT |
|
| 03/01/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* NW EXTERIOR STAIRWELL @ 5'4" -- OK TO GROUT |
|
| 02/14/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ENTRY AREA LINE E/4 TO E/5 @ 13'4" |
|
| 02/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) EXTERIOR WALL LINE E/3.75 TO E/4.5 AT 13'-4" 2) OK TO GROUT |
|
| 02/02/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) EXTERIOR WALLS C/6 TO C/7 AT 13'-4"; C/7 TO D.8/5 AT 10'-8" OK TO POUR |
|
| 01/31/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PERIMETER WALLS @ HAMBRO HEIGHT 13'4" LINES C/5 TO E/3 OK TO POUR |
|
| 01/30/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED - RAINED OUT |
|
| 01/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR WALLS @ 12'; LINES C/5 TO E/5 -- OK TO GROUT |
|
| 01/26/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* EXTERIOR WALLS: LINES E/3 TO B/5 @ 10'8" OK TO GROUT |
|
| 01/24/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* LINES B/5 TO E/4 @ 8' TO BOND BEAM OK TO GROUT |
|
| 01/16/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* OK TO GROUT @ 4' LINES A/3.5 TO E/3.5 |
|
| 10/04/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 0-24" OK TO GROUT |