Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2007 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* ELECTRIC ENCLOSURE @ 6'-8' - OK TO GROUT & CAP |
|
| 04/06/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) ARCHWAY AT 12' TOPPED OUT OK TO GROUT AND CAP | |
| 04/05/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ARCHWAY BETWEEN BLDGS B & C @ 8'10" -- OK TO GROUT |
|
| 03/28/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ARCHWAY BETWEEN BUILDINGS - B&C @ 54" -- OK TO GROUT |
|
| 03/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST SITE WALL @ 5' OK TO GROUT & CAP |
|
| 03/05/2007 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 10/12/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ARCHWAY @ BLDGS E&F @ 8' |
|
| 10/06/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ARCHWAY @ BLDGS E & F TO 4' -- OK TO POUR |
|
| 10/04/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 0-16" OK TO GROUT |
|
| 05/10/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | ||
| 05/08/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH WALL (WEST 1/4) 20'-23'4", WEST WALL 20'-23'4" NORTH WALL (WEST 1/4) 20'-23'4", NORTH WALL (EAST & WEST CENTER 1/4) 8'-12' |
|
| 05/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST WALL TO 20' NORTH WALL COLORED BLOCK TO 12'8" NORTH WALL GRAY BLOCK TO 20' |
|
| 04/28/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ENTRY TO TOP OF WALL, NORTH WALL (COLORED BLOCK) 4'-8' WEST WALL TO 15'4". |
|
| 04/24/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ENTRY TOWER TO 16' & SOUTH WALL (GRAY BLACK) TO TOP OF WALL |
|
| 04/21/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* COLORED BLOCK TOP OUT @ EAST & SOUTH WALLS - SOUTH WALL GRAY BLOCK TOP OUT & PARTIAL TO 15'4" (BLDG. A) |
|
| 04/20/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST 12" WALL - N&S EXTERIOR WALLS TO 11'4" |
|
| 04/19/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PERIMETER WALLS NE TO 15'6" TOWER TO 15'6" COLORED BLOCK TO 16' SOUTH WALL TO 16' |
|
| 04/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PERIMETER WALLS, WEST, SOUTH, PART OF NORTH 8'-12' |
|
| 04/03/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* E.W.S WALLS 4'-8' |
|
| 03/29/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* PERIMETER WALLS 0'-4'8" |
|
| 02/22/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* AREA BETWEEN BUILDINGS D-E (6'8"-11'4") |
|
| 02/13/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*BETWEEN BLDG D-3 ( 4'-6'8") BETWEEN C-D ( 6'8"-11'4" | |
| 01/25/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*ARCH WALLS BETWEEN BUILDINGS C-D & D-E ( 0-4') | |
| 01/11/2006 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TRASH ENCLOSURES FOR SITE (4'-7') TOPPED OUT |
|
| 01/05/2006 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* TRASH ENCLOSURES FOR SITE NOT READY |
|
| 12/30/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TRASH ENCLOSURES FOR SITE (0-4') |