Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/10/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) CANNOT APPROVE WITHOUT AN ORIGINAL INSPECTION CARD YELLOW | |
| 09/08/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) OUTSIDE METAL ELECTRIC BOX NOT GROUNDED FRONT AND REAR 2) RED HEAD ANCHOR BOLTS LOOSE THROUGHOUT 3) HTT 16 HOLDOWNS REQUIRE 5/8" BOLTS 4) ANCHOR BOLTS MISSING 5) SHEAR WALL 3 NOT NAILED IN GARAGE 6) STUD MISSING SHEAR WALL 7) NEED ORIGINAL INSPECTION CARD (YELLOW) |
|
| 09/07/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) AB LOOSE THRU OUT 2) NO TEST ON DWV 3) BLOCK VENT AT BATHROOM AND LIVING ROOM |