Permit: T04CM02839

Parcel: 107123850


Addresses:

2874 N BALBOA AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/24/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/01/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*/ 1) 3 PT BEARING TRUSSES TURNED END FOR END, NEED TRUSS REPAIR AT INTERIOE BEARING 2) A. BOLTS AT PLATE SPLICES 12" FROM EACH END 3) SMALL PIECE OF OSB TURNED WITH STRANDS PARALELL TO TRUSS NEEDS TO BE BLOCKED 4) FINISH FRONT PORCH ENTRY AND VERTICAL SHEATHING 5) OK TO DRY IN MAIN ROOF
09/13/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*/ 1) SIDING ON ALL UNITS APPROVED BY HEIGHT OF 8'