Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 01/24/2005 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection :* |
| 10/01/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection :*/ 1) 3 PT BEARING TRUSSES TURNED END FOR END, NEED TRUSS REPAIR AT INTERIOE BEARING 2) A. BOLTS AT PLATE SPLICES 12" FROM EACH END 3) SMALL PIECE OF OSB TURNED WITH STRANDS PARALELL TO TRUSS NEEDS TO BE BLOCKED 4) FINISH FRONT PORCH ENTRY AND VERTICAL SHEATHING 5) OK TO DRY IN MAIN ROOF |
| 09/13/2004 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection :*/ 1) SIDING ON ALL UNITS APPROVED BY HEIGHT OF 8' |