Permit: T04CM02821

Parcel: 136405260

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/03/2004 FRAMING Approved IVRS - Inspection :*
11/02/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
10/28/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) REPLACE STUD IN LAUNDRY CUT BY PLUMBERS 2) REPAIR HOLES MADE BY PLUMBERS 3) INSTALL GROUND WIRE TO GAS PIPE 4) T/P MUST FINISH WITHIN 12" OF GROUND 5) VENT ON FIREPLACE TO BE SUPPORTED EVERY 8'; NO LOAD ON FIREPLACE 6) INSULATION PROTECTION REQUIRED 7) REINSTALL AND BLOCK REGISTER IN MASTER TOILET