Permit: T04CM02816

Parcel: 131071760

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/02/2004 FRAMING Approved IVRS - Inspection :*
07/30/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) COMPLETE AND GET STUCCO MESH APPROVED PRIOR TO INTERMEDIATE INSPECTION 2) BANG PLATE MISSING AT EXTERIOR 3) PROVIDE WATER TEST-CHECK EXISTING PLUMBING FOR NAIL 4) MAKE-UP ALL ELECTRIC BOXES/SECURE WIRES 12" BOX FRAME
07/28/2004 FRAMING Denied IVRS - Inspection :
ALL WIRES MUST BE SECURED AT ALL FIXTURES
BANG PLATE WIRES WITHIN 1 1/4" OF STUD FACE
NEED DRAINAGE,WASTE,VENT TEST
SHIM HEADERS
RAISE WASHER BOX ABOVE THE FLOOD RIM OF THE WASHER AND AT LEAST 18" ABOVE THE TRAP
07/20/2004 FRAMING Not ready for Inspection IVRS - Inspection :*