Permit: T04CM02800

Parcel: 138241840

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/07/2004 FRAMING Approved IVRS - Inspection :*
09/22/2004 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*/ 1) WATER HEATER T & P LINE CANNOT EXHAUST GREATER THAN 18" ABOVE GRADE 2) NAIL PROTECT ALL WIRES WITHIN 1 1/4" OF STUD SURFACE 3) FURNACE "B" VENT INNER PIPE DAMAGED-REPLACE 4) LTT20 B WRONG LOCATION 5) RETURN AIR MUST PENETRATE SHEAR WALL PROVIDE DETAIL 6) SHEARWALL 9 REQUIRES 1/2" AA AT 16" ON CENTER 7) EXHAUST DUCT NOT OUTSIDE 8) MISSING EXHAUST FAN 9) STOPPED INSPECTION, NEXT FAILURE WILL BE CHARGED A REFEE
09/20/2004 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*/ 1) STUCCO LATH NOT COMPLETE 2) FURNACE "B" VENT INNER PIPE DAMAGED-REPLACE 3) O.S.B. SHEAR DAMAGED BY HAMMER HOLES. SMOOTH HOLES ONLY 4) STOPPED INSPECTION