Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/22/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950*/ 1) WATER HEATER T & P LINE CANNOT EXHAUST GREATER THAN 18" ABOVE GRADE 2) NAIL PROTECT ALL WIRES WITHIN 1 1/4" OF STUD SURFACE 3) FURNACE "B" VENT INNER PIPE DAMAGED-REPLACE 4) LTT20 B WRONG LOCATION 5) RETURN AIR MUST PENETRATE SHEAR WALL PROVIDE DETAIL 6) SHEARWALL 9 REQUIRES 1/2" AA AT 16" ON CENTER 7) EXHAUST DUCT NOT OUTSIDE 8) MISSING EXHAUST FAN 9) STOPPED INSPECTION, NEXT FAILURE WILL BE CHARGED A REFEE |
|
| 09/20/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950*/ 1) STUCCO LATH NOT COMPLETE 2) FURNACE "B" VENT INNER PIPE DAMAGED-REPLACE 3) O.S.B. SHEAR DAMAGED BY HAMMER HOLES. SMOOTH HOLES ONLY 4) STOPPED INSPECTION |