Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM02794

Parcel: 126180510


Addresses:

4009 E PASEO GRANDE

Inspection Status: Approved

Inspection History: BUILDING PRE-SLAB

Date Description Inspector Results Comments
08/16/2004 BUILDING PRE-SLAB Approved IVRS - Inspection :*
08/13/2004 BUILDING PRE-SLAB Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FOOTERS MUST BE 12" BELOW GRADE 2) NO REBAR IN FOOTING