Permit: T04CM02730

Parcel: 138133760


Addresses:

5748 S MANTA RAY RD

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/17/2004 FRAMING Approved IVRS - Inspection :*
09/16/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) 3" VERTICAL DRAIN LEAKING LIVING ROOM 2) INSTALL CEILING BACKING LIVING ROOM WEST WALL 3) NAIL OFF VERTICAL CHASE LIVING ROOM 3" VERTICAL DRAIN SOUTH WALL 4) FURR OUT 2ND FLOOR MASTER BATH WALL WEST, STAPLE IN DOUBLE LAV. TRAP ARM 5) BROKEN FITTING ON DRYER DUCT 6) BLOCK AT TUB SIDE MASTER 7) STUDS CUT IN HALF AT LAUNDRY 8) BANG PLATE ROMEX LIVING NEXT TO VERTICAL DRAIN WEST 9) PLUMBING OUT FO WALL WEST LIVING ROOM 1) BLOCK AND SECURE H20 SERVICE AT GARAGE
09/15/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) BLOCK DEFUSER BOOTS 3 SIDES 2) SEAL 2ND FLOOR PENETRATIONS 3) A/C ATTIC DISCONNECT REQUIRES 30" X 30" WORK AREA BLOCKED BY UNIT
09/14/2004 FRAMING Not ready for Inspection IVRS - Inspection :*