Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/17/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/16/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) 3" VERTICAL DRAIN LEAKING LIVING ROOM 2) INSTALL CEILING BACKING LIVING ROOM WEST WALL 3) NAIL OFF VERTICAL CHASE LIVING ROOM 3" VERTICAL DRAIN SOUTH WALL 4) FURR OUT 2ND FLOOR MASTER BATH WALL WEST, STAPLE IN DOUBLE LAV. TRAP ARM 5) BROKEN FITTING ON DRYER DUCT 6) BLOCK AT TUB SIDE MASTER 7) STUDS CUT IN HALF AT LAUNDRY 8) BANG PLATE ROMEX LIVING NEXT TO VERTICAL DRAIN WEST 9) PLUMBING OUT FO WALL WEST LIVING ROOM 1) BLOCK AND SECURE H20 SERVICE AT GARAGE | |
| 09/15/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BLOCK DEFUSER BOOTS 3 SIDES 2) SEAL 2ND FLOOR PENETRATIONS 3) A/C ATTIC DISCONNECT REQUIRES 30" X 30" WORK AREA BLOCKED BY UNIT |
|
| 09/14/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |