Permit: T04CM02720

Parcel: 123172500


Addresses:

1410 E LEE ST #01


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM02720

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/24/2005 FRAMING Approved IVRS - Inspection :*
01/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TO BE APPROVED WHEN ALL OTHER TRADES ARE COMPLETED
2) NO WATER IN DWV SYSTEM
3) PEX LINES OK
4) OK TO INSULATE
5) PLEASE LEAVE WASTE VENTS EXPOSED FOR INSPECTION
01/13/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK FIRE ALL DROPS
2) COMPLETE SHEAR PANEL PER PLAN
3) INSULATE BEHIND TUB/SHOWER WALLS
4) FASTEN BOTTOM 6" ON CENTER
5) COMPLETE WIRING TO A/C DISCONNECT
6) REVISE PLAN TO DELETE 125 AMP SUB-PANEL
7) SEAL HOME IN PENETRATIONS TO MAIN SERVICE
01/11/2005 FRAMING Partial Approval IVRS - Inspection :*
1) PARTIAL OK FOR INTERIOR SHEAR PANEL AREA ONLY
2) NO TEST ON TOP OUT