Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM02694
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 03/02/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT UNDERGROUND FROM END OF LINE CLEANOUT THRU BCD TO 2' PAST 2-WAY CLEANOUT OK. CORRECTION MADE. 1) WILL NEED TO VIEW TRAP PRIMER PIPING & PIPE WRAPS PRIOR TO CONCRETE POUR. TURNED IN LETTER FROM ENGINEER OK FOR ABS OR PVC FOR UNDERGROUND SEWER PIPING. | |
| 02/23/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) READ ALL NOTES ABOVE AND NOTES ON 2/18/05 INSPECTION SHEET IN TUBE. MAKE CORRECTIONS AND CALL FOR INSPECTION. |
|
| 02/18/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) I FOUND THE SPEC BOOK-NOW WHETER ARE THE PLANS? 20 SEE NOTE #3 -ABOVE. 3) NOT INSTALLED PER PLAN. SEE PIPING SERVICE SCHEDULE 15060-3 PIPING TO BE SERVICE WEIGHT CAST IRON. | |
| 02/15/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NO ONE ON SITE. 2) PLANS ARE INCOMPLETE WITHOUT SPEC. BOOK. PLEASE HAVE THIS AVAILABLE AT TIME OF NEXT INSPECTION. 3) NOTE: A TRAP ARM MUST BE AT LEAST 2X THE PIPE DIAMETER FROM THE WEIR OF THE TRAP TO THE POINT OF VENT. | |
| 01/28/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* NOT READY |