Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/17/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 02/02/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*2" T/L COPPER STUB UP AND OUT OF NORTH EAST CORNER FOR H20 SERVICE 60 PSI AIR TEST OK. WATER TEST ROUGH SOIL UNDERGROUND OK TO COVER. 1) CALL IN FOR INSPECTION FOR VIEWING OF PIPE WRAPS PRIOR TO CONCRETE POUR. | |
| 02/01/2005 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) HAVE YOUR YELLOW PERMIT CARD ON SITE!. WATER TEST FROM ?? OF LINE CLEANOUT THRU BUILDING TO 3' OUTSIDE NORTH END OF BUILDING PER PLAN ( PARTIAL APPROVAL) 2) TEST WILL BE REQUIRED FROM STUB THRU 2-WAY CLEANOUT TO HCS CONNECTION. 3) DO NOT COVER UNTIL YOUR YELLOW PERMIT CARD IS ON SITE AND HAS BEEN VIEWED BY INSPECTOR. | |
| 01/31/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE NOTE #1 FROM 1/24/05 2) INSTALL P-TRAP FOR P-4 FIXTURE WIHT WATER TEST. 3) END OF LIN? 90 DEGREE SHALL BE LONG RADIUS DRAINAGE FITTING |
|
| 01/26/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE A 10' OF HEAD FOR SOIL WATER TEST |
|
| 01/24/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PLEASE HAVE YOUR YELLOW PERMIT CARD ON SITE. 2) AIR OR WATER TEST PIPING AT TIME OF REINSPECTION. 3) HAVE ALL PIPING FOR UNDERGROUND COMPLETED |