Permit: T04CM02682

Parcel: 11714096A


Addresses:

460 S 6TH AV


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T04CM02682

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/02/2008 MECHANICAL - FINAL Approved
05/05/2006 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
04/28/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
CLOTHES DRIERS, VENTED UP THROUGH ROOF TERMINATIONS AND BASEMENT INSTALLATIONS TWENTY FIVE <25> TOTAL EXCEED MAXIMUM DEVELOPED LENGTH ALLOWED BY IMC SEC. 504/504.6.1
A G.E MODEL #DIR483EG WILL PROVIDE THE NECESSARY AIR TO MEET SEC. 504.6.1
04/26/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1. VERIFY THAT 180 DEG. ROOFTOP BEND IS INCLUDED IN DUCT LENGTH (+10')
2. VERIFY BACKDRAFT DAMPERS ARE NOT REQUIRED FOR ROOFTOP TERMINATION OF DRYERS.
3. 1/4" MESH REQUIRED AT ATTIC TERMINATION OF BOTH EXHAUST.
4. I DID NOT VERIFY HUMIDISTAT CONTROL OF ATTIC BLOWER
03/31/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
SEE SEC. 504.6
504.6.1
IMC DOMESTIC DRYER VENT LENGTH.