Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T04CM02682
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/02/2008 | PLUMBING - FINAL | Approved | ||
05/12/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* RM. 1105 PLUG REMOVED FROM DISPOSER, NO DW INSTALLED. VENTS THRU ROOF - OK ALL FIXTURES INSTALLED - OK CLEANOUTS - OK DW HOSES - OK T&P'S - OK ONLY REMAINING ISSUES ARE: 1. PLAN REVISION FOR LAUNDRY. 2. WATER HEATER SIZE AT MOP SINK LOCATION ABOVE LAUNDRY. 3. OLD ABANDON VENT PIPES STILL TAPED INTO PLACE THRU ROOF. THESE ARE NOT SUPPORTED IN ANY WAY, THE POSSIBILITY OF THEM FALLING THRU THE CEILING REMAINS. THESE NEED TO BE EITHER CAPPED AND SUPPORTED OR REMOVED. 4. IRRIGATION WATER BACKFLOW PREVENTER HAS BEEN INSTALLED, SUPPLY CERTIFICATION OF COMPLIANCE FOR RP |
|
05/10/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* NO REVISED PLAN ON SITE FOR JANITOR CLOSET W.H & LAUNDRY VENT. - VENTS HAVE NOT BEEN EXTENDED TO ABOVE ROOF. - AN ABANDONED PLUMBING VENT PENETRATES ROOF. - CUT DOWN AND INSTALL PLUG ON EXTERIOR CLEANOUT. - SOME CLEANOUT COVERS ARE MISSING. - SUPPORT EXPANSION TANKS THAT HAVE NOT YET BEEN SUPPORTED. - OPEN TRAP PRIMER VALVES. T&P DRAINS MISS FUNNEL ON GROUND FLR. - LAVATORY STOP NOT SEALING LAV BOWL. TUB DRAIN STOP MISSING. - SECURE AND ADJUST DISHWASHERS THAT NEED IT. - AZ STATE PLUMBING CODE SEC 807.4 ALLOWS A DISHWASHER DRAIN HOSE TO CONNECT DIRECTLY TO DISPOSER BOSS WITHOUT AN AIR GAP. THE DW DISCHARGE LINE SHALL BE SECURELY FASTENED AS HIGH AS POSSIBLE BUT IN NO CASE LESS THAN 2" BELOW FLOOD LEVEL. |
|
05/05/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
05/02/2006 | PLUMBING - FINAL | Not ready for Inspection | RE VENTS IN ATTIC NOT UNDER TEST. DISHWASHER DRAIN HOSES NOT SECURELY FASTENED. TUBS NOT CAULKED. |
|
03/31/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* REQUIRED FOR TCO 1. COMPLETE SEWER VENTS THRU ROOF. 2. COMPLETE DOMESTIC WATER BOOSTER PUMPS, CALL FOR YARD WATER INSPECTION. 3. COMPLETE SETTING OF ALL FIXTURES IN AREAS REQUIRING TCO. THIS INCLUDES DISHWASHERS AND CLEANOUT PLUGS. |