Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T04CM02682
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/27/2006 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
04/12/2006 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
04/10/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
03/31/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
03/28/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
03/23/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK R & R WALL OVER WASHER/DRYER IN 1106 |
|
03/16/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. UPPER LEVEL EXIT FIXTURES AT BALCONYS? NOT REALLY AN EXIT, NO STAIRS? OK DISCONNECTS FOR AIR HANDLERS IN CORRIDORS. 2. INSTALL LOCKOUTS IN CIRCUIT BREAKERS FOR AIR HANDLERS AND WATER HEATERS, COMPLETE COUNTERTOP RECEPTS IN KITCHENS, LIGHT FIXTURE IN 1205 |
|
02/24/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK SOFFITS 2ND LEVEL |
|
02/16/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* BASEMENT APPROVED OK TO COVER |
|
02/15/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK #1206 |
|
02/14/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CHECK REQUIREMENTS FOR DEVICE CURRENT RATING, SWITCHES AND RECEPTACLES. SUPPORT FEEDER CABLES TO PANEL ENCLOSURES 2) SUPPORT VERTICAL RUNS OF CABLES THRU FLOOR CHASES 3) OK PARTIAL ROOMS #1301, 1302, 1303 AND 1304 EXCEPT KITCHEN COUNTER RECEPTACLE BOXES, OK CEILINGS |
|
02/10/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. CHANGE OUT BOXES IN CEILINGS WHERE FANS ARE TO BE INSTALLED USE APPROVED SCREWS TO MOUNT. 2. CALL FOR INSPECTION FOR MAKE UP PRIOR TO TRIM 3. SUPPORT CABLES IN ATTIC 2ND FLOOR 4. SUPPORT PANELS IN UNIT WALLS 5. HAVE ELECTRICAL ENG. OR ARCH TO CLARIFY WIRING METHODS FOR SURFACE MTD. BRANCH CIRCUITS & DEVICES IN APTS. ALSO FEEDER TYPES, CONTRACTOR MATERIAL. 6. FAN COILS IN CORRIDORS TO HAVE DISCONNECTS FAN COILS IN UNITS OK TO HAVE LOCKOUT IN CIRCUIT BREAKERS USE HACK TYPE WATER HTRS DISCONNECTS AT UNITS OR LOCKOUTS AT BREAKERS. 7. TYPE NM ROMEX NOT APPROVED FOR UNDERGROUND USE. |
|
01/10/2006 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* TALKED ABOUT SERVICE |
|
12/29/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK CEILINGS IN APARTMENTS ONLY |
|
12/27/2005 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* ROMEX CONNECTORS REQUIRED IN METAL BOXES IN CEILINGS |
|
11/30/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
11/23/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :*OK WALLS HARD LIDS EXCEPT PANEL WALL | |
11/18/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :*OK 2ND FLOOR CORRIDORS, CALL FOR AIR HANDLER CONDUITS WHEN READY. | |
11/16/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :*OK WEST 1/2 OF GROUND FLOOR | |
11/14/2005 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
11/03/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :*OK 2ND FLOOR ROUGH | |
11/02/2005 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
10/21/2005 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK ROUGH 2ND 1301 & 1304 |