Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM02662
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/26/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAILS/STAPLES TO BE SET FINISH WITH SHEATHING 2) SHEATHING REQUIRES 1/8" GAP 3) INSTALL NAIL PROTECTION BOTTOM PLATES AT PLUMBING CUTS 4) S.W. 6 REQUIRES ANCHOR BOLTS 24" 5) NEED VERIFICATION OF ALL H2.5/A35/ATTACHMENTS LEDGER TO STUDS |