Permit: T04CM02662

Parcel: 103080110

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM02662

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/04/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
01/26/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILS/STAPLES TO BE SET FINISH WITH SHEATHING
2) SHEATHING REQUIRES 1/8" GAP
3) INSTALL NAIL PROTECTION BOTTOM PLATES AT PLUMBING CUTS
4) S.W. 6 REQUIRES ANCHOR BOLTS 24"
5) NEED VERIFICATION OF ALL H2.5/A35/ATTACHMENTS LEDGER TO STUDS