Permit: T04CM02650

Parcel: 136406240

Inspection Status: Approved

Inspection History: STUCCO MESH

Date Description Inspector Results Comments
11/22/2004 STUCCO MESH Approved IVRS - Inspection :*
11/10/2004 STUCCO MESH Partial Approval IVRS - Inspection :*/ 1) COMPLETE AROUND WINDOW
2) 1 WINDOW MISSING
3) NAIL ? GARAGE UNDER GLU LAM
4) LOOSE WIRE IN 4R ?
5) NAIL STRAPS
6) MOVE BOXES OUT TO NEW WALL
7) SUPPORT TUB MASTER BATH
8) 1" CLEARANCE TO B-VENT
9) FURNACE B-VENT NOT INSTALLED