Permit: T04CM02642

Parcel: 103184040


Addresses:

2480 W PRICHETT PL

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
07/07/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
07/06/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 2000 IRC SECTION 2604.1 ROCKY SOIL SHALL BE OVER EXCAVATED BY TWO OR MORE PIPE DIAMETERS AND BROUGHT TO GRADE WITH SUITABLE COMPACTED GRANULAR MATERIAL NO LARGER THAN 3/16" 2) BACK FILL 12" ABOVE PIPING OF ? EARTH IN 6' LIFTS AFTER INSPECTION APPROVED 2000 IRC 2604.3 WITH NO LARGER THAN 3/16" MATERIAL