Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T04CM02609
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/13/2004 | ROOF NAILING | Approved | IVRS - Inspection :* | |
08/10/2004 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :*/ 1) OVER FRAMING AT GARAGE 2 X 8 ATTACHING TO A 2 X 4 TOP CHORD. NEED LIG OR BLK ACCROSS LIKE A LEDGER FOR THE THREE LONG RAFTERS 2) PANELS NOT FINISHED, MISSING 2 X MATERIAL, PLUMBER, MECHANICAL CUT OUT MEMBERS, PLUMBER TO REMOVE VENT. OSB NOT NAILED TO SIDES OF PANELS 3) TRUSS ON EAST END TOO MANY CUTS IN TOP CHORD, ONE HOLE TOO BIG HAVE TRUSS CO CERTIFY 5) ISSUES WITH ROOF NEED TO TALK TO SUPER | |
08/06/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
07/29/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |