Permit: T04CM02595

Parcel: 119010740


Addresses:

310 E BENSON HY

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
08/13/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
08/12/2004 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
07/23/2004 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) SEE 314.16 (B) FOR ALLOWABLE WIRE FILL (HANDY BOXES ARE TOO SMALL FOR THE AMOUNT OF WIRE FILL) 2) REVISE PLAN ON ADDED RECEPTACLES (HAVE AVAILABLE AT FINAL INSPECTION) 3) RACEWAYS APPROVED FOR BURIEL ONLY WHERE CONCRETE ENCASED, SHALL REQUIRE CONCRETE ENVELOP NOT LESS THAN 2" THICK TABLE 300.5 NOTE 2