Permit: T04CM02560

Parcel: 116214230


Addresses:

1423 W KANDY CT

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
11/07/2005 BUILDING - FINAL Approved IVRS - Inspection :*
10/31/2005 BUILDING - FINAL Partial Approval IVRS - Inspection :*
NEED PHOTO VOLTIAC INSPECTION (FINAL) APPROVED SEPARATE PERMIT
10/27/2005 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) CAULK AROUND TUB
2) SINGLE WALL PIPE FURNACE TO HAVE 6" CLEARANCE TO COMBUSTIBLES
3) H20 HEATER FLUE TO HAVE POSITIVE FLOW AND REMOVE TAPE AT TRANSITION TO DBL WALL
4) NEED STUCCO CARD
5) EXTEND CONDENSATE AND H20 HEATER POP OFF TERMINATION TO 6" -18" OF GROUND
6) COMPLETE GRADING
7) NEED INSPECTION OF P.V. SYSTEM