Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/29/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 04/18/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED PERMIT/PLANS FOR SOLAR SYSTEM 2) INSTALL EPC POST TO BEAMS PER PLAN 3) MOVE ROMEX AWAY FROM FLUE PIPE 4) MAINTAIN 1" CLEARANCE FLUE PIPE TO WOOD 5) EXTEND FLUE PIPE INTO FURNACE ROOM 6) CONNECT GAS BOND |
|
| 04/11/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL PLATE BOLTS WITHIN 12" EACH END BOTTOM PLATES 2) CUT OFF MANTEL FIREPLACE TO MANUFACTURERS SPECS 3) INSTALL ? ALL POSTS TO BEAMS 4) 10 POUND TEST REQUIRED 5) COMPLETE CEILING FURNACE ROOM 6) SECURE ELECTRIC WIRES AWAY FROM FLUE PIPE 7) MAINTAIN MINIMUM 1" CLEARANCE FLUE PIPES TO COMBUSTIBLE 8) NEED PLAN CHANGE ADDING ELECTRIC GARGE 9) BLOCKING MISSING THRU-OUT 10) STRAP BEAMS AT BEARING 11) NEED ENGINEERED APPROVED DETAIL PORCH LEDGERS TO BEARING 12) ALL ITMES INCOMPLETE 13) STOPPED INSPECTION 14) REFEE DUE |
|
| 04/01/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STOPPED INSPECTION 2) INSTALL DROPPED CEILING FURNACE COMPARTMENT AND FIREBLOCK 3) MANTEL EXTENSION FIREPLACE EXCEEDS MANUFACTURERS LIMITS 4) INSTALL LAG BOLTS PORCH LEDGERS 5) GARAGE LEDGER LAGS BOLTS NOT PER PLAN 6) KITCHEN FLOOR WET-CHECK FOR LEAKS 7) INSTALL BOLTS WITHIN 12" EACH END BOTTOM PLATES |
|
| 03/16/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK ALL SIDES MECH VENTS GARAGE (MECH) (EXTERIOR WALL) 2) CAULK ALL PENETRATIONS LATH 3) WHAT ARE ELECTRIC BOXES AND CONDUIT FOR GARAGE ? ON PLAN ? 4) NO TEST DWV 5) INSTALL GAS PIPING BOND 6) INCOMPLETE SET OF PLANS 7) INSTALL DROPPED CEILING FURNACE ? HEATER AREA AND FIREBLOCKS 8) STOPPED INSPECTION |