Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T04CM02556

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/05/2005 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :* 28 UNITS.
03/31/2005 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) FINISH ALL LOW VOLTAGE & C?? WIRING INC TV 2) ALL PANELS TO HAVE SUPPORT BOTH SIDES. 3) SUPORT ALL HOME RUNS INTO PANELS WITHIN 12". 4) STRAP & NAIL WIRING HANGING OUT OF WALLS WITH NO BOXES. 5) CANNOT HAVE BOXES WITH UN-USED CABLE ENTRY KNOCKED OUT. 6) TOO MUCH UNFINISHED WIRING 1ST FLOOR PLEASE CHECK ALL WIRING BE FOR INSPE.