Permit: T04CM02519

Parcel: 13323360D


Addresses:

231 N PANTANO RD


Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T04CM02519

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
05/27/2005 SITE - SEWER Approved IVRS - Inspection :*
05/26/2005 SITE - SEWER Approved 1) 6" SITE SEWER FROM MANHOLE BACK TO EXISTING
2) 4" BLDG HCS CONNECTION INCLUDING IN LINE CLEANOUT REQUIRED BECAUSE OF EXCESS OF 100' FROM BLDG 2-WAY CLEANOUT
3) 4 PSI AIR TEST OK
4) PIMA COUNTY TO INSPECT MANHOLE
05/25/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
1) MANHOLE AND STUB OUT FOR NEW HCS OK TO COVER MANHOLE
05/23/2005 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
03/10/2005 SITE - SEWER Partial Approval IVRS - Inspection :*
1) SOIL WATER TEST IS OK
2) NOTE: THIS INSPECTION IS FOR THE BLDG SEWER FROM TWO WAY CLEANOUT TO PROPERTY LINE ONLY
3) OK TO BACKFILL TRENCH
4) SHALL SEE HCS MAIN TAP INO EASEMENT
03/09/2005 SITE - SEWER Not ready for Inspection IVRS - Inspection :* WILL NEED TO TALK W/TRINI
03/02/2005 SITE - SEWER Denied 1) SHALL PROVIDE MINIMUM OF 2'-0" FROM CITY WATER MAIN
2) RETEST SYSTEM