Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/16/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/08/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GABLE END TRUSS NOT BEARING ON POST OR DBL TOP PLATE AT ENTRY POST 2) PLANS ON SITE EXPIRED 2/03. PROVIDE CURRENT PLAN 3) TRUSS T-04 AND T-05 BRACING NOT INSTALLED 4) SHEAR WALLS MUST EXTEND TO ROOF DECK PER 15/10 5) PLAN CALLS FOR MST 27 PER 4/10 AT CARPORT, ENTRY AND BATHROOM NOT COMPLIED WITH 6) STOPPED INSPECTION |
|
| 11/24/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection :FAILURE - REFEE BEFORE CONTINUING | |
| 11/19/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) STRAP TOP PLATES PER DETAIL 4/10 AT BEAMS BEFORE ROOFING 2) STRAP TOP PLATES PER DETAIL 4/10 AT BEAMS BEFORE ROOFING |
|
| 11/14/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) STRAP TOP PLATES PER DETAIL 4/10 2) 4/10 FOR BEAM LOCATIONS, INSTALL STRAPS BEFORE ROOFING |
|
| 11/01/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEED ANCHOR BOLTS ON NORTH EAST GARAGE WALL 2) STRAP TOP PLATES PER DETAIL 4/10 3) ENTRY COLUMN NEEDS OSB ON 4 SIDES PER PLAN |
|
| 10/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NUMBERS 6 AND 7 NOT DONE 2) EXTERIOR OSB INSTALL NOT COMPLETE |
|
| 10/22/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | 1) MISSING WIND BRACING WEST AND SOUTH WALLS 2) T04, T05, TRUSSES REQUIRED LATERAL BRACING 3) NAIL ALL CORNERS VERTICAL 24" ON CENTER 4) TOO MUCH SPALLING AT SOME P.A.'S MET RETRO FIT H.D.'S 5) RUN ALL SHEAR UP TO BOTTOM OF ROOF SHEATHING 60 MISSING A.B. AND NUTS AT COLUMNS 7) 4/10 FOR BEAM LOCATIONS, INSTALL STRAPS BEFORE ROOFING |