Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/05/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PLUMBING AND PLASTIC ELECTRIC CONDUITS WITHIN 1 1/2" OF BOTTOM PLATE SURFACES MUST BE NAILED PROTECTED 2) NO LADDER TO INSPECT ROOF |
|
| 08/04/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) STUD AT SOUTH WEST CORNER OF GARAGE TO SHORT 2) ANCHOR BOLTS IN COLUMN MISSING NUTS 3) PROVIDE CRIPPLE ABOVE HEADER BOTH SIDES OF SLIDING GLASS DOOR 4) CRIPPLES NOT BEARING UNDER WINDOW 5) STRAP 2 X 6 WALL AT PATIO 6) NAIL PROTECT PLUMBING FROM OUTSIDE 7) STOPPED INSPECTION |