Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/26/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/01/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) OK TO INSULATE AND DRYWALL 2) LESS THAN 15" SIDE CLEARANCE FROM W/C TOILET TO TUB HALL BATH | |
| 08/30/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) 1) REQUIRED HEAD ANCHOR BOLTS LOOSE 2) NO TRUSS DRAWINGS ON SITE-CHECK WEB BRACING 3) SECURE WIRES WITHIN 8" OF BOXES 4) HOLDOWN AND SHEARWALL 5 MISSING AT DINING ROOM-FP OPTION 5) HOLDOWN MISSING BAY WINDOW 6) HOLDOWN MISSING BATHROOM SHEAR 7) PROVIDE DETAIL FOR SHEARWALL 5 TO TRUSS CONNECTION AT GARAGE 8) FIRE BLOCK ENTRY NITCH AT GARAGE 9) LESS THAN 15" SIDE W/C CLEARANCE FOR HALL BATH. POPOUTS NOT COMPLETE, SEAL PENETRATIONS 10) MANU TRUSSES MISSING CLIPS ON INTERIOR BEARING 11) 2 FIRE BLOCKS MISSING KITCHEN SLIDING GLASS DOOR 12) FIREBLOCK MISSING M. BATH |